Product · Liquid Cooling产品 · 液冷
L1800C45 L1800C45DR220 45ft 1800 kW Liquid Cooling container · dual loop · GPU 36–45 °C · CRAH 10/16 °C · no UPS · up to 220 kW/rack · Coming soon45 英尺 1800 kW 液冷集装箱 · 双回路 · GPU 36–45 °C · 列间空调 10/16 °C · 无 UPS · 最高 220 kW/机柜 · 即将推出

Higher rack density
in a 45 ft liquid block.
更高机柜密度
装进 45 英尺液冷模块。

Your GPUs are ready before your building is. L1800C45 removes the building: 1,800 kW of training capacity in one factory-tested container — GB300 NVL72 / B300 HGX density, connected to power, water, and network in days, earning in 75–90 days on repeat orders. 机柜就绪往往早于土建。L1800C45 用集装箱替代大楼: 单台工厂测试的集装箱提供 1,800 kW 训练容量 — 支持 GB300 NVL72 / B300 HGX 密度,数日接通电、水、网, 复购订单可在 75–90 天内创收。

Runs CIOS · →运行 CIOS · →
1800 kW
IT CapacityIT 容量
up to 220 kW/rack
Power Density · R220功率密度 · R220
Dual loop
GPU 36–45 °C · CRAH 10/16 °CGPU 36–45 °C · 列间 10/16 °C
~6 mo → 75–90 d
First Unit → Repeat首台 → 复购
01
What L1800C45 isL1800C45 是什么

Two water systems. One dual-loop design.两套供水系统。一套双回路设计。

You've seen the business case — modular blocks, BESS-first power, time-to-revenue. L1800C45 is the Computing Unit in that equation: a 45-ft High Cube container with dual independent water systems. One loop supplies the GPUs at 36–45 °C through cold plates; a second chilled-water loop at 10/16 °C feeds in-row (CRAH) cooling for residual heat. Everything is integrated, tested, and sealed at the factory — on site you connect power, water, and network. 商业逻辑你已经看过——模块化区块、BESS 优先供电、投产时间。 L1800C45 就是这个等式里的计算单元:一台 45 英尺高柜集装箱,采用 两套独立供水系统。一路以 36–45 °C 经冷板服务 GPU; 另一路以 10/16 °C 冷冻水供给列间空调(CRAH)处理其余热负荷。所有系统在工厂 完成集成、测试与封装——现场只需接入电、水、网。

Form Factor外形形态
45-ft High Cube container45 英尺高柜集装箱
SKU ID
L1800C45DR220
IT CapacityIT 容量
1,800 kW
Cooling冷却
Dual loop · GPU 36–45 °C · CRAH 10/16 °C双回路 · GPU 36–45 °C · 列间空调 10/16 °C
UPS
Not included不含
Density密度
Up to 220 kW/rack (R220)最高 220 kW/机柜(R220)
Status状态
Coming soon即将推出
Lead Time交付周期
After Publish发布后开放

IT Load vs. Facility Load. 1800 kW is what the servers draw. Total facility load is higher once cooling and auxiliaries are added — the gap is set by PUE, which depends on your site's climate. *Cold, dry sites land at the low end. Always confirm which figure an "X MW" requirement refers to. IT 负荷与设施总负荷。1800 kW 指服务器实际用电。计入冷却与辅助系统后, 设施总负荷更高——差值由 PUE 决定,而 PUE 取决于站点气候。 *寒冷干燥的站点落在区间下限。遇到「X MW」的需求时,务必确认指的是哪一个口径。

L1800C45 liquid cooling container cutaway poster
L1800C45 — dual loop: GPU warm water 36–45 °C and chilled-water CRAH 10/16 °C.L1800C45 — 双回路:GPU 温水 36–45 °C,冷冻水列间空调 10/16 °C。
02
Why Direct Liquid Cooling为何选择冷板直接液冷

For SXM-class clusters, DLC isn't an upgrade. It's the entry ticket.对 SXM 级集群来说,液冷不是升级项,而是入场券。

Liquid cooling density

It unlocks the density它解锁了密度

A cold plate in direct contact with the GPU carries heat out through water — supporting up to 220 kW/rack, the regime NVLink platforms require and air cooling cannot reach. Junction temperature stays precisely controlled under sustained training load. 冷板与 GPU 直接接触,靠水把热量带走——支撑 最高 220 kW/机柜,这正是 NVLink 平台所需、而风冷无法达到的区间。 在持续训练负载下,结温始终被精确控制。

Warm-water efficiency

Two loops for two heat paths两套回路,两条排热路径

L1800C45 uses two water systems: a 36–45 °C loop for GPU cold plates (high-temperature, free-cooling friendly) and a separate 10/16 °C chilled-water loop for in-row CRAH units that handle residual rack and room heat. That split keeps GPU cooling efficient while air-side cooling stays on a classic chilled circuit. L1800C45 采用两套供水系统:一路 36–45 °C 服务 GPU 冷板 (高温回路,利于自然冷却),另一路独立 10/16 °C 冷冻水服务列间空调(CRAH), 处理机柜与室内余热。GPU 侧保持高效液冷,空气侧仍走经典冷冻水回路。

Factory-built module

The complexity is ours, not yours复杂度归我们,不归你

DLC adds real engineering — coolant loops, leak detection, redundant pumps. L1800C45 absorbs all of it into one tested, standardized module. You get the density without owning the integration risk. 液冷确实增加了工程量——冷却回路、漏液检测、冗余泵。L1800C45 把这些全部吸收进 一个经过测试的标准化模块。你拿到密度,却不必承担集成风险。

03
Walk through it走进去看看

Explore L1800C45 in 3D以 3D 浏览 L1800C45

Preview the 45 ft high-density Liquid Cooling container — gullwing doors and rack access. Coming soon as a full published product.预览 45 英尺高密度液冷集装箱 — 鸥翼门与机柜通道。完整产品页在发布后开放。

MDCX L1800C45 liquid cooling container

Reference design download (OpenUSD)参考设计下载(OpenUSD)

  • L1800C45 · L1800C45DR220L1800C45 · L1800C45DR220 DLC45-1800KW.usdc.xz
    Download下载

Heavy USD is explicit download only. Specs: USD output.大体积 USD 仅显式下载。规格见 USD 输出

04
Go deeper深入了解

Inside the technical deep-dive技术细节一览

The full engineering model is live and interactive — every number computed from the same physics engine our design team uses, referenced to ASHRAE W50 and the NVIDIA GB300 design envelope. 完整工程模型可在线交互——每个数字都来自我们设计团队所用的同一套物理引擎, 参照 ASHRAE W50 与 NVIDIA GB300 设计包络。

Cold plate detail

Interactive 3D container交互式 3D 集装箱

Walk the rack rows, piping, and cooling units of the actual L1800C45 layout.在真实的 L1800C45 布局中查看机柜列、管路与冷却设备。

Telemetry

Thermal load breakdown热负荷拆解

See how 1.8 MW of heat splits across cold plates, rear doors, and room air.看清 1.8 MW 热量如何在冷板、后门换热器与室内空气之间分配。

Coolant loop

Dual water systems双路供水系统

GPU loop at 36–45 °C and CRAH chilled loop at 10/16 °C — two circuits, two setpoints.GPU 回路 36–45 °C,列间空调冷冻水 10/16 °C — 两套回路、两套设定点。

Global deployment

Power & PUE by climate按气候的功耗与 PUE

Set your site's ambient conditions and watch efficiency respond.设定站点环境条件,实时观察效率变化。

Ready to see the engineering?
Configuration is engineered by MDCX — pricing goes through your account manager.